EB-G3042 Germicidal Lamp Electronic Ballast (10–40W)
Purpose: Electronic ballast designed to drive germicidal (UV) lamps in UV disinfection/sterilisation systems.
Handy built-in display: Shows Lamp Life Remaining (Days) and Total Running (Days), with alarm/indicator LEDs.
Important: Indoor use only. For use in permanently connected (fixed) equipment only (as marked on the ballast label).
Why choose this ballast
- Wide input range: 110–240V AC, 50/60Hz
- Supports common germicidal lamp sizes: 10–40W
- Onboard monitoring: lamp life remaining + total runtime counters
- Status indicators: Buzzer, Alarm, Fault LED, Work LED
- Designed for reliability in fixed UV equipment
How the display & controls work
Display screens
- Lamp Life Remaining (Days)
- Total Running (Days)
Button functions (as labelled)
- Press to switch display screens between lamp and ballast
- Press to display total running days of ballast
- Press & hold to reset lamp life timer
- Press & hold to silence end-of-lamp-life alarm for 7 days (up to 4 times max)
Performance
| Electrical | |
|---|---|
| Input | 110–240V AC, 50/60Hz |
| Max. input current | 0.44A @ 110V or 0.20A @ 240V |
| Lamp power range | 10W–40W |
| Lamp current | 0.39A–0.42A |
| Environment & monitoring | |
|---|---|
| Ambient temperature | −15°C to 40°C |
| Tc max | 70°C |
| Lamp rated life counter | 365 days |
| Label notes | Class P • High Power Factor • Fixed equipment only |
In the box
- EB-G3042 electronic ballast (digital display & indicators)
- Mains power lead (AU plug shown in image)
- Lamp connection lead/connector (as pictured)
Best practice (UV systems)
- Replace your UV lamp on schedule (the ballast’s counter helps you stay on top of it).
- Keep the ballast mounted where airflow is reasonable and temperature stays within spec.
- If your system alarms or shows a fault, check lamp seating/connection first, then lamp condition.
Model: EB-G3042 (Germicidal Lamp Electronic Ballast)